StaglinCenter:EEG: Difference between revisions

From Center for Cognitive Neuroscience
Jump to navigation Jump to search
No edit summary
(→‎EEG Facilities & Equipment: add info about bio-semi eeg suite)
 
(17 intermediate revisions by 2 users not shown)
Line 2: Line 2:




The Staglin EEG Suite is part of the [http://www.semel.ucla.edu/staglin Staglin IMHRO Center for Cognitive Neuroscience] and contains resources including:
==EEG Facilities & Equipment==
*[http://www.egi.com/research-division-research-products/eeg-systems/251-conventional-eeg EGI Net Amps 300]
The Staglin EEG Suite is part of the [http://www.semel.ucla.edu/staglin Staglin IMHRO Center for Cognitive Neuroscience] and contains resources including two fully shielded EEG suites and a prep room.
*[http://www.egi.com/research-division-research-products/eeg-systems/191-ges300mr MR-safe EGI Net Amps 300]
*[http://www.egi.com/research-division-research-products/sensor-registration EGI Photogrammetry System]
*[http://www.egi.com/research-division-research-products/sensor-nets EGI HydroCel EEG Nets] - S/M/L of MR and non-MR compatible versions


The Left EEG Suite:
*[https://www.egi.com/images/stories/manuals/GES_300/GES_300_tman_8103003-51_20150304_hires.pdf EGI Net Amps 300]
*[https://www.egi.com/images/stories/placards/legacy/PIB_instructions_plac_8404162-51_20100427.pdf Polygraph Input Box (PIB) for Net Amps 300]
*[https://www.egi.com/images/stories/company/documents/net_amps_400_flyer_oct_2015_MM_421.pdf MR-safe EGI Net Amps 400]
*[https://www.egi.com/research-division/geodesic-sensor-net EGI HydroCel EEG Nets] - S/M/L of MR and non-MR compatible versions
The Right EEG Suite:
*Bio-Semi 64 channel EEG system using active electrodes


==Using the EEG Suite==
==Using the EEG Suite==
This page describes step-by-step how to schedule, set-up, and test in the Staglin EEG Suite:  [[StaglinCenter:EEG:Testing]]
This page describes step-by-step how to schedule, set-up, and test in the Staglin EEG Suite:   
*[[StaglinCenter:EEG:Testing]]


'''We recommend giving these directions a complete once-over before you ever take data here.'''
'''We recommend giving these directions a complete once-over before you ever take data here.'''


==Troubleshooting and Denoising==
==Troubleshooting and Denoising==
*[[Checking Ground]]
*[[Checking Ground]]
*[[Checking for wire loops]]
*[[Checking for Wire Loops]]
*[[Checking Scanner Settings]]
*[[Checking Scanner Settings]]
*[[Checking Cap Electrodes for Noise]]
*[[Checking Cap Electrodes for Noise]]


==EEG Suite supplies==
===Where to find EEG supplies in the lab===
Most of the supplies needed for EEG testing is located in the EEG net room in the wooden cabinet by the sink.  If you open the left cabinet, on the main top shelf, most of the supplies you will need for testing will be located in the plastic bin labeled with EEG supplies.  You will find the following in that bin:
*'''scissors'''
*'''red wax pencil'''
*'''tape measure'''
*'''spandages'''
*'''disposable EEG/MR electrodes'''


'''Johnson's baby shampoo''', '''EEG solution salt''', '''extra electrodes''', '''the EGI net manual''', and '''EGI net boxes'''  along with their respective measuring spoons are usually located on top of the cabinet by the sink. The electrodes and the net boxes are in the cardboard boxes on top of the cabinet.
==EGI Net Maintenance==
*[https://www.egi.com/images/stories/manuals/Printed%20IFUs%20with%20New%20Notified%20Body/HC_GSN_RM_sponged_appl_uins_8403481-53_20181210.pdf Procedure for Routine Net Tests]
*[https://docs.google.com/forms/d/1qYeNEjPSWKaGmElK9eYHlLOpIOF6R5L1tYh1l861R4E/viewform EGI Net Check-Up Form]
*[https://docs.google.com/spreadsheets/d/1Gx4vqWxGfCX9JPs5AoBQcIU4OveudAx9vv4XIcNJ8YQ/edit#gid=332429759 EGI Net Check-Up Log]


In the EEG Suite's left testing room, you will find remaining supplies in the cabinets to the left of the table with the computer monitor and the EGI amp.  The cabinet shelves are labeled with these items:
*'''latex gloves'''
*'''disinfectant'''
*'''pipettes'''
*'''medical tape'''
*'''EEG salt'''


If you see that something has run out, check the following places to see if extras are stored:
==EEG Suite supplies==
*the wooden cabinet by the sink the EEG net room (Johnson's baby shampoo and spandages may be hiding in the shelf below the plastic bins, in the bottom drawers, or on top of the cabinet)
*[[Where to find EEG supplies]]
*the cabinets in the EEG suite (currently, there are MANY boxes in the right-most cabinet in the testing room and some on the top shelf of the cabinet where the Stimulus computer lives).
*[[Where to order EEG supplies]]
<!---*[[Current supply stock]]--->


'''NOTE:'''  If something has completely run out, there is an emergency supply located in the shop, but please ask Agatha, Sam, or Cameron for these supplies.  BUT ONLY FOR EMERGENCIES.


===Where to order EEG supplies===
==Current Projects==
We have had success ordering supplies from the following places.  The ones ordered from online sites accept purchase orders:
===Concurrent EEG/fMRI===
*'''pipettes''' (5.8mL, non-sterile):  [http://www.fishersci.com/ecomm/servlet/fsproductdetail?storeId=10652&productId=634785&catalogId=29104&matchedCatNo=1371120||137119AM||137119CM||137119BM&fromSearch=1&searchKey=pipette||pipettes||pipeters||pippette||pipettor||pipetter||pipeter||pipettors||pipetters&highlightProductsItemsFlag=Y&endecaSearchQuery=%23store%3DScientific%23nav%3D0%23rpp%3D25%23offSet%3D0%23keyWord%3Dpipettes%23searchType%3DPROD%23SWKeyList%3D Fisher Scientific]
*[[SWM Concurrent]]
*'''MT Spandages''' (MT07, 7-inch spandage, 25 yards):  [http://www.vitalitymedical.com/mt-spandage-tubular-elastic-dressing.html Vitality Medical MT Spandage] 
*'''Johnson's baby shampoo''':  This is very hard to find online, so purchase from a store (CVS, Target, Walgreens, etc.) and give the bank statement and receipt to Jun or Malina for a reimbursement.
*'''EGI KCL salt''':  order from EGI by e-mail supportteam@egi.com
*'''Control3 disinfectant''':  e-mail control3@earthlink.net - order the 16 oz. bottle.
*'''GSR electrodes''' (EL509, 100 electrodes/box):  [http://www.biopac.com/disposable-radiotranslucent-dry-electrode Biopac Systems, Inc.]
*'''Self-Adhesive Bandage''' (Item 2082, 2 inch x 5 yards, latex-free):  [http://www.vitalitymedical.com/coban-self-adherent-wrap.html Vitality Medical Self-Adhesive Wrap]
 
===Current supply stock===
*'''pipettes''':  ordered 2014.01.10 - 10 boxes of 500 pipettes
*'''Johnson's baby shampoo''':  ordered 2014.01.20 - 8 bottles
*'''MT Spandages''':  ordered 2014.08.06 - 10 boxes
*'''GSR electrodes''':  ordered 2014.2.12 - 2 boxes of 100 electrodes
*'''Control III Disinfectant''':  ordered 2014.4.4 - 3 16 oz. bottles
*'''EGI KCL Salt''':  ordered 2014.3.27 - 5 tubs
*'''Self-Adhesive Bandage''':  ordered 2014.3.15 - 36 rolls
 
==Current EEG Projects==
*[[StaglinCenter:EEG:SSVEP]]




Line 71: Line 49:
If you want to take EKG data concurrently...
If you want to take EKG data concurrently...
*[[StaglinCenter:EEG:EKG]]
*[[StaglinCenter:EEG:EKG]]




==External Links==
==External Links==
*[http://www.egi.com EGI]
*[http://www.egi.com EGI]
*[http://www.egi.com/research-division-research-products/eeg-systems/251-conventional-eeg EGI Amp]
*[https://www.egi.com/research-division/net-amps-eeg-amplifier EGI Amp]
*[http://www.egi.com/research-division-research-products/eeg-systems/191-ges300mr EGI MR Safe Amp]
*[https://www.egi.com/images/stories/manuals/GES_400/core/GES_400MR_uman_8100401-55_20150722_hires.pdf EGI MR Safe Amp]
*[http://www.egi.com/research-division-research-products/sensor-registration EGI Photogrammetry System]
*[https://www.egi.com/knowledge-center EGI Knowledge Center]

Latest revision as of 23:18, 26 September 2021

This page will give you general information about the EEG Suite including how to use the testing rooms, EGI net information, current EEG projects, and where to locate and order supplies.


EEG Facilities & Equipment

The Staglin EEG Suite is part of the Staglin IMHRO Center for Cognitive Neuroscience and contains resources including two fully shielded EEG suites and a prep room.

The Left EEG Suite:

The Right EEG Suite:

  • Bio-Semi 64 channel EEG system using active electrodes

Using the EEG Suite

This page describes step-by-step how to schedule, set-up, and test in the Staglin EEG Suite:

We recommend giving these directions a complete once-over before you ever take data here.


Troubleshooting and Denoising


EGI Net Maintenance


EEG Suite supplies


Current Projects

Concurrent EEG/fMRI


Related Info

EKG

If you want to take EKG data concurrently...


External Links