Hoffman2 maintenance and Issues

From Center for Cognitive Neuroscience
Revision as of 18:18, 15 October 2021 by Hwang (talk | contribs)
Jump to navigation Jump to search

Issues and Solutions

Update date: 2021.10.15

Here's a list of the known issues after Hoffman2 maintenance

  • Known issue 1.

x2go and noMachine interface looks froze or in full screen mode, user cannot find menu bar.

Solution:

If you are using GNOME as the desktop interface, please change to MATE. KDE works as well but you might have to delete the ~/.x2go and ~/.x2goclient in your local machine (with MacOS).


  • Known issue 2.

FSLeyes in FSL 6.0.4 and 6.0.3 does not load GUI on x2go and noMachine (Other versions work, as well as fslview)

Solution (for both x2go and noMachine):

For FSLeyes in FSL 6.0.4, type in the following command line after you start interactive session, and before you run fsleyes

unset LIBGL_ALWAYS_INDIRECT

For FSLeyes in FSL 6.0.3, fsleyes will be upgraded shortly to fix the current issue.


  • Known issue 3

FreeView GUI opens but not loading images successfully

Solution:

In noMachine, use "unset LIBGL_ALWAYS_INDIRECT" command should fix the issue

In x2go, "unset LIBGL_ALWAYS_INDIRECT" does not seem to work all the time. We are still looking into it.